selection guide....
Accurate measuring is essential.
Instructions
It is very important that you provide accurate measurements so that the most efficient and economical pumping plant can be recommended to suit your requirements. First choose the diagram from the Selection Guide that is most similar to your proposed site. Answer the general data questions with accurate measurements and include pumping details.
Winds, especially the light breezes, must have free access to the mill from all directions. The bottom of the wheel must be at least 15ft (4.5metres) above all wind obstructions within 150yds (137 metres) of the mill.
Elevations
The mill should be loaded and balanced so that it will start pumping in light breezes. Its size depends upon the size of the pump and total elevation. The latter includes not only the vertical heights for suction and delivery elevations but also an allowance for probable water flow friction in the pipeline. The delivery pipe size should be at least half the pump diameter.
Suction
In a bore or well it is best to submerge the pump. For a creek or dam the pump should be placed close to the water and the suction elevation must not exceed 30ft (9m), or less if the suction pipeline is long.